WINDOWS
...
WINDOWS

More than meets the eye

What is a space all about? Atmosphere, people that inhabit and use it, the feeling of belonging? Is it about boundaries? Separating what is inside from what is outside? Space is all about you. What you consider important. We create the frame that shapes your vision, keeps it safe and makes it beautiful.

Technologies

ELVIAL's steps to perfection. A key factor in the rapid growth of ELVIAL has been its ongoing investment of substantial capital innovative ideas and the application of state-of-the-art technologies and totally vertical profile and system processing and production.
Lorem Ipsum 2
ELVIAL PRE-ANODIZING 2IN1
Lorem Ipsum 1
ELVIAL I2 TECHNOLOGY

Window Systems

Iconic W77 AI2 ML_BS Iconic W77 AI2 CE_BS Iconic W77 AI2 ML Iconic W77 AI2 CE
DESIGN
System Depth mm 77 77 77 77
Min Face Height
Frame-Sash
mm 66 66 89 89
Min Face Height
Threshold-Sash
mm 56 - 79 -
Min Face Width
Middle Mullion
mm 78 107 154 154
Design Minimal Design
Linear Design
Minimal Design
Linear Design
Linear Design Linear Design
PROPERTIES
Max Sash Height mm 2.400 2.400 2.800 2.800
Max Sash Width
mm 1.200 1.200 1.600 1.600
Max Sash Weight
kg 130 130 200 200
Max Glass Thickness mm 46 or 32 46 or 32 66 66
Mechanism Type Multilock groove
mechanism [ML]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
European groove
mechanism [CE]
Surface Finishings All All All All
PERFORMANCE
Uf value (≥)
EN ISO 10077-2
W/m²K 1.4 1.4 0.88 0.88
Air Permeability
EN 12207
Class 4 Class 4 Class 4 Class 4
Water Tightness
EN 12208
E750 E750 E1200 E1200
Wind Load Resistance
EN 12210
C5/B5 C5/B5 C5/B5 C5/B5
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(450 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Iconic W77 ST AI2
DESIGN
System Depth mm 77
Min Face Height
Frame-Sash
mm 68
Min Face Width
Middle Mullion
mm 89
Design Minimal Design
Industrial Design
PROPERTIES
Max Sash Height mm 2.400
Max Sash Width
mm 900
Max Sash Weight
kg 130
Max Glass Thickness mm 56
Mechanism Type European groove
mechanism [CE]
Surface Finishings All
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Essence W67 HI2 ML_BS Essence W67 HI2 CE_BS Essence W67 HI2 ML Essence W67 HI2 CE
DESIGN
System Depth mm 67 67 67 67
Min Face Height
Frame-Sash
mm 66 66 89 89
Min Face Height
Threshold-Sash
mm 56 - 79 -
Min Face Width
Middle Mullion
mm 78 107 154 154
Design Minimal Design
Linear Design
Minimal Design
Linear Design
Linear Design Linear Design
PROPERTIES
Max Sash Height mm 2.400 2.400 2.800 2.800
Max Sash Width
mm 1.200 1.200 1.600 1.600
Max Sash Weight
kg 130 130 200 200
Max Glass Thickness mm 46 or 28 46 or 28 57 57
Mechanism Type Multilock groove
mechanism [ML]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
European groove
mechanism [CE]
Surface Finishings All All All All
PERFORMANCE
Uf value (≥)
EN ISO 10077-2
W/m²K 1,8 1,8 1,1 1,1
Air Permeability
EN 12207
Class 4 Class 4 Class 4 Class 4
Water Tightness
EN 12208
E1050 E1050 E1050 E1050
Wind Load Resistance***
EN 12210
C5/B5 C5/B5 C5/B5 C5/B5
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
W59 SI2 ML W59 SI2 ML_RD W59 SI2 CE W59 SI2 CE_RD
DESIGN
System Depth mm 58.6 69 58.6 69
Min Face Height
Frame-Sash
mm 102.1 102.1 94.1 102.1
Min Face Height
Threshold-Sash
mm - - 107.5 -
Min Face Width
Middle Mullion
mm 155.7 155.7 155.7 155.7
Design Linear Design [LD] Rounded Design [RD] Linear Design [LD] Rounded Design [RD]
PROPERTIES
Max Sash Height mm 2.400 2.400 2.400 2.400
Max Sash Width
mm 1.200 1.200 1.200 1.200
Max Sash Weight
kg 130 130 130 130
Max Glass Thickness mm 46 35 46 35
Mechanism Type Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
European groove
mechanism [CE]
European groove
mechanism [CE]
Surface Finishings All All All All
PERFORMANCE
Uf value (≥)
EN ISO 10077-2
W/m²K 2.16 2.5 2.16 2.5
Air Permeability
EN 12207
Class 4 Class 4 Class 4 Class 4
Water Tightness
EN 12208
E900 E900 E900 E900
Wind Load Resistance***
EN 12210
C4/B4 C4/B4 C4/B4 C4/B4
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
  • Elvial Facebook Instagram Twitter YouTube Pinterest Pinterest Google Plus LinkedIn Previous Next